Advanced Horizontal Pressure Sterilizer for Medical Equipment Safety

Customization: Available
Theory: Autoclave
Type: Pressure Steam Sterilization Equipments

Product Description

Basic Parameters
Model NO.CK-150/200/280YDB
CertificationCE, ISO13485
MaterialStainless Steel
Power380V 50Hz
Volume Options150L / 200L / 280L
Temperature Range40-134 Degree
Sterilization Time0-99 min
Alarm SystemUltra High Temp Alarm
Horizontal Pressure Steam Sterilizer

Microcomputer Control System

The horizontal autoclave adopts the gravity exchange method to release cold air from the chamber completely, ensuring reliable sterilization. The control system automatically adjusts steam inlet and outlet based on chamber temperature. It is ideal for clinics, scientific research institutes, and organizations sterilizing surgical instruments, fabrics, glassware, and culture media.

Horizontal Pressure Sterilizer Overview
Key Features & Characters
  • Automatically controlled sterilizing process, easy to operate.
  • Integrated drying function, suitable for medical dressing drying.
  • Over-temperature and over-pressure auto-protection systems.
  • Safety door interlock: Door cannot open until chamber pressure is below 0.027MPa.
  • Safety valve opens automatically if inner pressure exceeds 0.24MPa.
  • Automatic power cut-off and alarm for water-lack conditions.
  • High-quality stainless steel chamber construction.
  • Equipped with a built-in printer for sterilization records.
Technical Specifications
Specifications CK-150YDB CK-200YDB CK-280YDB
Sterilizing Chamber Volume 150L (φ440×1000mm) 200L (φ515×1000mm) 280L (φ600×1000mm)
Working Pressure 0.22 MPa
Working Temperature 134ºC
Temp. Adjustment Range 40ºC - 134ºC
Sterilization/Drying Time 0-99 min
Heat Average ≤± 2ºC
Power Consumption 9KW / 380V 9KW / 380V 12KW / 380V
Dimension (mm) 1400×650×1600 1400×750×1700 1520×910×1900
G.W/N.W (KG) 430/340 436/350 570/462
Detailed Product Photos
Production & Quality Control
Shipping Preparation
Frequently Asked Questions
Q1: What materials can be sterilized with this horizontal autoclave? A: It is suitable for surgical instruments, medical fabrics, glassware, and culture media used in clinics and laboratories.
Q2: Does the sterilizer include a drying function? A: Yes, it features a drying function that is particularly suitable for drying medical dressings after sterilization.
Q3: What safety mechanisms are in place for pressure control? A: It includes a safety valve that opens automatically at 0.24MPa and a door interlock system that prevents opening until pressure drops below 0.027MPa.
Q4: How does the microcomputer control system benefit the user? A: It automates the entire sterilizing process, regulates steam flow based on temperature, and includes a printer for automated record-keeping.
Q5: What happens if the water level is too low? A: The unit will automatically cut off power and trigger an alarm to prevent damage to the equipment.
Q6: Is the sterilization chamber durable? A: Yes, the chamber is constructed from high-grade stainless steel for long-term durability and corrosion resistance.

Related Products